-- Part I InnoMedia ESBC MIBs, -- ************************************************************************** -- Part I ,This is InnoMedia ESBC MIB tree -- ************************************************************************** ESBC-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises,MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, ObjectName, Integer32, Counter32, Unsigned32, snmpModules, IpAddress FROM SNMPv2-SMI DisplayString, TestAndIncr, TimeStamp, DateAndTime, RowStatus, TruthValue,TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF ifIndex FROM IF-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB sysDescr FROM SNMPv2-MIB; -- version 8 innomedia OBJECT IDENTIFIER ::= { enterprises 3354 } voiceoverip OBJECT IDENTIFIER ::= { innomedia 1 } clientline OBJECT IDENTIFIER ::= { voiceoverip 3 } esbc MODULE-IDENTITY LAST-UPDATED "0701220000Z" -- Jan. 22, 2007 ORGANIZATION "InnoMedia Engineering" CONTACT-INFO " Phone: +1 408-432-5400 " DESCRIPTION "This MIB module supplies the basic management objects for ESBC" ::= { clientline 2 } snmpVar OBJECT IDENTIFIER ::= { esbc 1 } voice OBJECT IDENTIFIER ::= { snmpVar 1 } management OBJECT IDENTIFIER ::= { snmpVar 3 } esbcSystem OBJECT IDENTIFIER ::= { snmpVar 4 } network OBJECT IDENTIFIER ::= { snmpVar 5 } monitoring OBJECT IDENTIFIER ::= { snmpVar 6 } trap OBJECT IDENTIFIER ::= { snmpVar 7 } control OBJECT IDENTIFIER ::= { snmpVar 8 } lineInfo OBJECT IDENTIFIER ::= { snmpVar 9 } sipServerInfo OBJECT IDENTIFIER ::= { snmpVar 10 } hardwareInfo OBJECT IDENTIFIER ::= { snmpVar 11 } -- Defination of MIB objects under management(3) group boxUserName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Administrator User Name." ::= { management 1 } boxPassword OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "Administrator Password." ::= { management 2 } deviceType OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Device type for EMS management. The device needs to be rebooted by set 'systemReset' to 1 after this variable is set." ::= { management 6 } regionID OBJECT-TYPE SYNTAX INTEGER (0..100000) MAX-ACCESS read-write STATUS current DESCRIPTION "Device region ID for EMS management. The device needs to be rebooted by set 'systemReset' to 1 after this variable is set." ::= { management 7 } firmwareRemoteUpdateURL OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "URL for firmware remote update." ::= { management 8 } -- Defination of MIB objects under esbcSystem(4) group systemVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The system version includes model name, firmware version, bootloader version, hardware version." ::= { esbcSystem 1 } systemPCICFunctionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The system PCIC function ID." ::= { esbcSystem 2 } -- Defination of MIB objects under network(5) group localIPMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Local WAN Mask or OAMP IF." ::= { network 1 } localDefaultGWIP OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Local WAN Default gateway IP or OAMP IF." ::= { network 2 } localIP OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Local WAN IP or OAMP IF." ::= { network 3 } domainName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address or QDN for this device." ::= { network 5 } boxMacAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address for this device." ::= { network 6 } boxServerDns1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the WAN primary DNS server or OAMP IF." ::= { network 7 } boxServerDns2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address or QDN of the WAN secondary DNS server or OAMP IF." ::= { network 4 } localDefaultGWMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Local WAN Default gateway Mask, should be same as localIPMask or OAMP IF." ::= { network 8 } snmpManagerIP OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap Managner's IP. The device needs to be rebooted by set 'systemReset' to 1 after this variable is set." ::= { network 9 } snmpCommunity1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Read-Only Community name and access right. The device needs to be rebooted by set 'systemReset' to 1 after this variable is set." ::= { network 10} snmpCommunity2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Read-Write Community name and access right. The device needs to be rebooted by set 'systemReset' to 1 after this variable is set." ::= { network 11} nameEMS OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..100)) MAX-ACCESS read-write STATUS current DESCRIPTION "EMS sever1 name, FQDN or IP address. The deivce needs to be rebooted by set 'systemReset' to 1 after this variable is set." ::= { network 12 } portEMS OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "EMS sever1 port number. The device needs to be rebooted by set 'systemReset' to 1 after this variable is set." ::= { network 13 } boxServerDns3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved." ::= { network 14 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- | -- The interface Port Table | -- | -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ interfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF interfaceEntry ACCESS not-accessible STATUS current DESCRIPTION "A list of configuration entries for Ethernet individual interface ports." ::= { network 15 } interfaceEntry OBJECT-TYPE SYNTAX interfaceEntry ACCESS not-accessible STATUS current DESCRIPTION "Configuration parameters for an individual interface port." INDEX { interfaceIndex } ::= { interfaceTable 1 } interfaceEntry ::= SEQUENCE { interfaceIndex INTEGER, interfaceDescription DisplayString, interfaceType INTEGER, interfaceSpeedAdminStatus INTEGER, interfaceSpeedOperStatus INTEGER, interfaceAdminStatus INTEGER, interfaceOperStatus INTEGER, interfaceDuplexAdminStatus INTEGER, interfaceDuplexOperStatus INTEGER, interfaceStormControl INTEGER, interfaceFlowControl INTEGER, interfaceFlowControlThresholdTransmitOn INTEGER, interfaceFlowControlThresholdTransmitOff INTEGER } interfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Number greater than zero identifying an individually interface port. The same value of port index variable for any of the port tables in this MIB group selects the same port." ::= { interfaceEntry 1 } interfaceDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(0..60)) ACCESS read-only STATUS current DESCRIPTION "A descriptive string of up to 60 characters used by the network administrator to name a port. LAN Port 1, LAN Port 2, LAN Port 3, LAN Port 4, WAN Port 1, WAN Port 2" ::= { interfaceEntry 2 } interfaceType OBJECT-TYPE SYNTAX INTEGER { other(1), Ethernet(6) } ACCESS read-only STATUS current DESCRIPTION "Identifies whether the port is other : none of the following Ethernet : Ethernet port" ::= { interfaceEntry 3 } interfaceSpeedAdminStatus OBJECT-TYPE SYNTAX INTEGER { auto-negotiate(1), auto-negotiate-10Mbps-100Mbps(2), auto-negotiate-10Mbps (3), 1000Mbps(4), 100Mbps(5), 10Mbps(6) } ACCESS read-write STATUS current DESCRIPTION "Set to auto-negotiate(1),(2),(3) to allow the interface to negotiate with the other end of the connection. (4) is reserved. Set to (5),(6) to desired speed of the port." DEFVAL { auto-negotiate } ::= { interfaceEntry 4 } interfaceSpeedOperStatus OBJECT-TYPE SYNTAX INTEGER { Unknown(1), 1000Mbps(2), 100Mbps(3), 10Mbps(4) } ACCESS read-only STATUS current DESCRIPTION "Indicates the current port speed status of a port." ::= { interfaceEntry 5 } interfaceAdminStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS current DESCRIPTION "By explicit management action, change the port status to either enabled : transmit and receive enabled as NAT port. For fixed Management port, still enabled as Management port. disabled : transmit and receive disabled. This behavior will trigger reboot to take effect." DEFVAL { enabled } ::= { interfaceEntry 6 } interfaceOperStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), up(1), down(2) } ACCESS read-only STATUS current DESCRIPTION "Current operational status of the port. Possible values are: up : normal operation (transmit and receive) down : the port is currently in the down state disabled : disabled by explicit management action" ::= { interfaceEntry 7 } interfaceDuplexAdminStatus OBJECT-TYPE SYNTAX INTEGER { auto-negotiate(1), half-duplex(2), full-duplex(3) } ACCESS read-write STATUS current DESCRIPTION "Set to auto-negotiate(1) to allow the interface to negotiate with the other end of the connection. The half-duplex(2) is to manually set for half-duplex and full-duplex(3) is to manually set for full-duplex." DEFVAL { auto-negotiate } ::= { interfaceEntry 8 } interfaceDuplexOperStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), half-duplex(2), full-duplex(3) } ACCESS read-only STATUS current DESCRIPTION "Indicates whether the port is operating in half- duplex, full-duplex. If the port could not agree with the far end on port duplex, the port will be in unknown(1) mode." ::= { interfaceEntry 9 } interfaceStormControl OBJECT-TYPE SYNTAX INTEGER (0..11) ACCESS read-write STATUS current DESCRIPTION "The current broadcast and multicast forwarding control of this port. If this port is suppressed by storm control, the interface discards all broadcasts and multicasts beyond the threshold of maximum value 11 for 9x platform. disabled(0), 1k-fps(1), 2k-fps(2), 4k-fps(3), 8k-fps(4), 16k-fps(5), 32k-fps(6), 64k-fps(7), 128k-fps(8), 256k-fps(9), 512k-fps(10), 1M-fps(11) (maximum value 4 for 8x platform) disabled(0), 159 packets/10ms for 100Mbps port(1), 127 packets/10ms for 100Mbps port(2), 63 packets/10ms for 100Mbps port(3), 31 packets/10ms for 100Mbps port(4)" DEFVAL { 11 } ::= { interfaceEntry 10 } interfaceFlowControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(0) } ACCESS read-write STATUS current DESCRIPTION "The configuration of flow control on this port. Flow control allows the port to throttle packet transmission according to flow control messages sent by the other end of the link. For ports that do not support the feature, this object is always set to disabled." DEFVAL { enabled } ::= { interfaceEntry 11 } interfaceFlowControlThresholdTransmitOn OBJECT-TYPE SYNTAX INTEGER (16..256) MAX-ACCESS read-write STATUS current DESCRIPTION "When block memory used by one port is less than this value, the MAC will send out a pause off frame and the link partner will begin to transmit frames." DEFVAL { 48 } ::= { interfaceEntry 12 } interfaceFlowControlThresholdTransmitOff OBJECT-TYPE SYNTAX INTEGER (16..256) MAX-ACCESS read-write STATUS current DESCRIPTION "When block memory used by one port is more than this value, the MAC will send out a pause on frame and the link partner will stop transmitting frames. Threshold of transmit off must be greater than threshold of transmit on." DEFVAL { 64 } ::= { interfaceEntry 13 } nameEMS2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..100)) MAX-ACCESS read-write STATUS current DESCRIPTION "EMS sever2 name, FQDN or IP address. The device needs to be rebooted by set 'systemReset' to 1 after this variable is set." ::= { network 16 } portEMS2 OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "EMS sever2 port number. The device needs to be rebooted by set 'systemReset' to 1 after this variable is set." ::= { network 17 } localIPVoiceIF OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Local WAN IP or Voice IF." ::= { network 18 } localIPMaskVoiceIF OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Local WAN Mask or Voice IF." ::= { network 19 } localDefaultGWIPVoiceIF OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Local WAN Default gateway IP or Voice IF." ::= { network 20 } boxServerDns1VoiceIF OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the WAN primary DNS server or Voice IF." ::= { network 21 } boxServerDns2VoiceIF OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address or QDN of the WAN secondary DNS server or Voice IF." ::= { network 22 } -- Defination of MIB objects under monitoring(6) group b2buaCurrentActiveCalls OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " The number of B2BUA active calls. " ::= { monitoring 19 } -- Defination of MIB objects under trap(7) group -- traps for esbc battery acFailure NOTIFICATION-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " AC Failure,only for ESBC " ::= { trap 14} replaceBattery NOTIFICATION-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " Replace Battery,only for ESBC " ::= { trap 15} batteryMissing NOTIFICATION-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " Battery Missing,only for ESBC " ::= { trap 16} batteryLow NOTIFICATION-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " Battery Low,only for ESBC " ::= { trap 17} poorVoiceQualityThreshold NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that detected the MOS threshold call. " ::= { trap 19} sipRegistrationFailure NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that detected SIP registration failure. " ::= { trap 20} failedLoginAttempts NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that detected the LOGIN failure threshold. " ::= { trap 21} emergencyCallAlarm NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that detected the EMERGENCY call occurs. " ::= { trap 22} provisioningSuccessOrFailure NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that notified the success or failure to provision firmware or configurations. " ::= { trap 23} concurrentCallsLimitReached NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that notified the max system capacity of concurrent calls reached. " ::= { trap 24} managementControlStateChange NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that detected the state of management control is changed. " ::= { trap 25} priReceivedReleaseProtocolError NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that received release complete message with cause code of protocol errors. " ::= { trap 26} priDchannelUpDown NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that detected PRI Dchannel up or down. " ::= { trap 27} priRemoteBchannelOutOfService NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " PRI B-channel x that received Remote Out of Service. " ::= { trap 28} interfaceLANPhysicalLinkDown NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The host that detected LAN interface link down. " ::= { trap 29} sntpUnsychronized NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Indicate the SNTP client is unsychronized. " ::= { trap 30} fanFailure NOTIFICATION-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " HW Fan Failure,only for ESBC10K " ::= { trap 31} -- Defination of MIB objects under control(8) group systemReset OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "System reset control 1: true (Reset system) 2:false (Not reset system)." DEFVAL { 2 } ::= { control 1 } dhcpEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "WAN DHCPC enable or not 1:true (Enable) 2:false (Disable). The ESBC need to be rebooted by set 'systemReset' to 1 after this variable is set" ::= { control 2 } provisioningEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "provisioning enable control 1:true (Enable) 2:false (Disable)." DEFVAL { 1 } ::= { control 5 } emsTCPReq OBJECT-TYPE SYNTAX DisplayString (SIZE (0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "to set ems TCP server by telnet://ip:port or http://ip:port" REFERENCE "initial ems" ::= { control 13 } emsHBRedirect OBJECT-TYPE SYNTAX DisplayString (SIZE (0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "(Reserved)to reset ems HB server" REFERENCE "ip:port interval(ms)" ::= { control 14 } reProvisioning OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "set ESBC to do reprovisioning 1:true (to do now) 2:false." DEFVAL { 2 } ::= { control 15 } wanWebSrvEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable wan Web service access 1:true , 2:false." DEFVAL { 2 } ::= { control 17 } systemFactoryReset OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "System factory reset control 1: true (Reset factory default) 2: false (Not factory reset system)." DEFVAL { 2 } ::= { control 18 } firmwareRemoteUpdate OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Trigger remote update for system SW 1: true (to do now) 2: false" DEFVAL { 2 } ::= { control 19 } -- end of control group -- Defination of MIB objects under lineInfo(9) group lineInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF LineInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes SIP Trunk line information." ::= { lineInfo 1 } lineInfoEntry OBJECT-TYPE SYNTAX LineInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of supported line information." INDEX { lineInfoIndex } ::= { lineInfoTable 1 } LineInfoEntry ::= SEQUENCE { lineInfoIndex INTEGER, channelEnable TruthValue, userID DisplayString, userPassword DisplayString, registerStatus INTEGER } lineInfoIndex OBJECT-TYPE SYNTAX INTEGER (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index value which uniquely identifies an entry in the lineInfoTable." ::= { lineInfoEntry 1 } channelEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Enable/Disable this line" ::= { lineInfoEntry 10 } userID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "user ID or subscriber ID of this line." ::= { lineInfoEntry 11 } userPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "user Password or call processing password of this line." ::= { lineInfoEntry 12 } registerStatus OBJECT-TYPE SYNTAX INTEGER{ signIn (1), signOff (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "register status of this line." ::= { lineInfoEntry 15 } --end of lineInfoTable numberOfLines OBJECT-TYPE SYNTAX INTEGER (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "number of SIP Trunk lines present in the device." ::= { lineInfo 2 } -- ESBC MIBs for sipServerInfo group proxyIPList OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "string of Multi proxy IP or FQDN." ::= { sipServerInfo 1 } -- ESBC MIBs for hardwareInfor group hardwareID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "hardware version ID for the ESBC box." ::= { hardwareInfo 1 } -- end of hardwareInfo group --end of snmpVar group vLanInfo OBJECT IDENTIFIER ::= { esbc 8 } vLanTaggingEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "vLan Tagging Enable on WAN interface." ::= { vLanInfo 1 } vLanTOSEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "(Reserved)vLan IP TOS TO 802.1p priority mapping enable for NATed traffic on WAN interface." ::= { vLanInfo 2 } vLanID OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "vLanID for NATed traffic on WAN interface." ::= { vLanInfo 3 } priority OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "vLanID priority for NATed traffic on WAN interface." ::= { vLanInfo 4 } --- end of InnoMedia ESBC MIBs END