The Company Products Partners Press Room Sales Support
 

eUPS 1230 Specifications
Uninterruptible Power Supply

Features | Specifications

Communication Signal Interface


The telemetry Signal interface allows the eUPS 1230 to output information regarding the health of the UPS. Pins 4, 5, 6, and 7 on the UPS side provide the necessary telemetry signals as defined by PacketCable.

Vo+
: +Voltage output
   
Vo- : -Voltage output
   
SIG RTN : Signal Return
   
ON BATT : Low when operating from utility line. Open when operating from battery.
   
REPLACE BATT : Low when battery is charged. Open when battery fails the Self Test which is conducted once a month.
   
BATT MISSING : Low when battery is present. Open when battery is missing. Signal updated once every 10 secs.
   
LOW BATT : Low when battery is near full charge capacity. Open when operating from a
battery with < 20% capacity.

eUPS 1230 Status Indicators

eUPS front
Green indicates the UPS is on utility (AC) power.
Red indicates the UPS is in fault Fault
Yellow indicates the UPS is on battery power
Silence Switch for Buzzer Enable/Disable

Specifications

INPUT

Nominal input voltage

120Vac
Acceptable Input Voltage Range
85-260Vac
Acceptable Input frequency Range 45Hz~65Hz
Inlet IEC inlet

OUTPUT

Output power (max)
30W
Normal Output Power
26.4W (12V x 2.2A)
Normal Voltage
12Vdc
Output Voltage Range
10.5V~13.8V
Output Transfer Time
0 millisecond
Line Mode Efficiency
> 80%
Output Protection
Replaceable 10A fuse (with fuse holder soldered on PCB)
BATTERY Type/Rating
12V/9Ah*1pc
Discharge Prevention
10.5V ± 0.5V
Rated Charging Voltage 4 hours to 90% without load after complete discharge
Charge Current
4 hours to 90% without load after complete discharge
Charge Current
2.5A Maximum
Hot Swappable Battery Yes
INDICATOR AC mode
Green LED Lighting
Backup mode
Yellow LED Lighting
Battery low Yellow LED Flashing
Battery replace
Red LED Flashing
Battery missing
Red LED Lighting
Fault
Red LED Lighting
Battery self-test*
Green LED flashing
AUDIBLE ALARM Backup mode Sounding every 5 seconds
Battery low Sounding every 1 second
Battery replace
Sounding every 2 seconds
Battery missing
Continuous sounding
Fault
Continuous sounding

PHYCICAL SPECIFICATION

Weight of unit 7.72lbs (3.5kg)
Depth x Width x Height of unit
9.45in x 7.09in x 3.15in
(240mm x 180mm x 80mm)
OPERATING ENVIRONMENT Operating temperature
32ºF to 104ºF (0ºC to 40ºC)
Operating humidity
0% to 90%
Operating Elevation
0 to 9842.52ft (0 to 3000m)
CERTIFICATION FCC/UL Approved, IEC6100-4-5 Tested

* Occurs on initial AC power on and every 30 days thereafter